عربي

Sounders, Strobes & Bells

Fire alarm notification devices are the end output of the fire system, alerting occupants that immediate evacuation is required. They include electromechanical bells, electronic sounders with multiple tone patterns, visual strobes/beacons for the hearing-impaired and high-noise areas, and combined sounder-beacon units.

(0 products)

About this category

Notification appliances carry the evacuation message from the system to the occupants. General design: a red plastic enclosure (standard), the sounding element (electromechanical for bells, electronic for sounders, high-power LED for strobes), wiring to the control panel, and a fixed base. Types: electromechanical bells (vibrating-hammer mechanism, classic strong tone without rattle, common in factories), electronic sounders (digital with several tone patterns: continuous, swept, interrupted; varying for different states), visual strobes/beacons (LED flashes at 1-2 Hz, essential for hearing-impaired and noisy environments above 90 dB), combined sounder-beacon units, and voice-alarm devices (recorded voice messages in multiple languages, used in large multi-story buildings). Typical sound level: 100-120 dB at one meter. General install guidance: sounder at least 2.1 m above the floor, at a level ensuring adequate audibility at any point in the building (per the adopted code, noise levels and occupancy, e.g. 15 dB above average ambient under NFPA 72), strobe in the middle of a space for visibility from corners. Precise coverage and sound-level requirements follow the building code and project specification. Power: from the panel's Notification Appliance Circuit, or amplified in large buildings. Applications: all buildings with an alarm system. A technical note: substantive differences among types — bells for ordinary sites, sounders for sites with normal noise, strobes essential for the hearing-impaired and noisy industry. Maintenance: quarterly audio-visual test, annual wiring integrity check.

Read more

Notification appliances carry the evacuation message from the system to the occupants. General design: a red plastic enclosure (standard), the sounding element (electromechanical for bells, electronic for sounders, high-power LED for strobes), wiring to the control panel, and a fixed base. Types: electromechanical bells (vibrating-hammer mechanism, classic strong tone without rattle, common in factories), electronic sounders (digital with several tone patterns: continuous, swept, interrupted; varying for different states), visual strobes/beacons (LED flashes at 1-2 Hz, essential for hearing-impaired and noisy environments above 90 dB), combined sounder-beacon units, and voice-alarm devices (recorded voice messages in multiple languages, used in large multi-story buildings). Typical sound level: 100-120 dB at one meter. General install guidance: sounder at least 2.1 m above the floor, at a level ensuring adequate audibility at any point in the building (per the adopted code, noise levels and occupancy, e.g. 15 dB above average ambient under NFPA 72), strobe in the middle of a space for visibility from corners. Precise coverage and sound-level requirements follow the building code and project specification. Power: from the panel's Notification Appliance Circuit, or amplified in large buildings. Applications: all buildings with an alarm system. A technical note: substantive differences among types — bells for ordinary sites, sounders for sites with normal noise, strobes essential for the hearing-impaired and noisy industry. Maintenance: quarterly audio-visual test, annual wiring integrity check.

No products in this category yet

Browse the similar categories, or request a quote for what you need and we will source it.