عربي
Honeywell AERIS Confort Type 2 SCBA, Composite 7 L — 18251111/7
1/7
Honeywell AERIS Confort Type 2 SCBA, Composite 7 L — 1825111
Honeywell

Honeywell AERIS Confort Type 2 Self-Contained Breathing Apparatus 1825111 — Zenith Demand Valve, Panoramasque Full-Face Mask with 5-Point Head Strap, 7 L 300 bar Carbon Composite Cylinder, 45-Minute Duration, End-of-Operation Whistle, EN 137:2006 Type 2, SOLAS and MED, for Firefighting and Industry

Honeywell AERIS Confort Type 2 SCBA with Zenith demand valve, Panoramasque full-face mask and 7 L 300 bar carbon composite cylinder, 45 minutes; EN 137:2006. Read more

Availability

In stock

Product code (SKU)
HONEYWELL-1825111-AQL
Delivery time
2–3 business days
Sales unit
طقم

Price on request

Work out the quantity for your project

How many do you need? Enter the number of workers, the length of the project and how often each item is replaced.

Suggested quantity · Sales unit: طقم

30

Workers (10) × project days (90) ÷ days between replacements (30) = 30. Counted in pieces.

Product details

تفاصيل المنتج

Overview

The Honeywell AERIS Confort 1825111 is a Type 2 self-contained breathing apparatus set for firefighting and industry, with a Zenith demand valve, a Panoramasque full-face mask and a 7 L 300 bar carbon composite cylinder, to EN 137:2006.

  • Air supply: a 7 L carbon composite cylinder at 300 bar for a 45-minute duration; the cylinder is supplied empty.
  • Zenith demand valve: the stage 2 regulator; compatible with both demand and positive-pressure quick-click valves.
  • Panoramasque full-face mask: with a polycarbonate lens and a 5-point head strap.
  • Harness: a black polypropylene and aramide backpack harness with waist belt, on a non-metallic, flexible back plate.
  • Monitoring: a pressure gauge and an end-of-operation alarm whistle.
  • Handling: 3 carry handles and flame-retardant reflective pads on the shoulders.
  • Approvals: EN 137:2006 Type 2, SOLAS, MED, IMO, MSC and ISO 23269-3.

Available on Armexia for project and volume supply across all regions; request a quote for bulk orders.

Technical Specifications

CategorySelf-Contained Breathing Apparatus
BrandHoneywell
Product familyAERIS Confort
Product typeSelf-contained breathing apparatus (SCBA), Type 2
Set reference1825111
Face maskPanoramasque full-face mask, 5-point head strap
Mask lensPolycarbonate
Demand valveZenith (stage 2 regulator)
Valve compatibilityDemand and positive-pressure quick-click valves
CylinderCarbon composite, 7 L, 300 bar (supplied empty) · Ref. 1824852
Duration45 minutes
Pressure gauge300 bar – 7 L
AlarmEnd-of-operation whistle
HarnessPolypropylene and aramide, black, with waist belt
Back plateNon-metallic, ergonomic, flexible
Carry handles3
Reflective padsFlame-retardant, on the shoulders · Ref. 1825338
Carrying caseRef. 1824852 (as stated)
Standards and approvalsEN 137:2006 Type 2 · SOLAS · MED · IMO · MSC · ISO 23269-3
ApplicationsFirefighting · Industry
Country of originFrance
Sales unitطقم
Model (MPN)1825111-7L
Item identifier (SKU)HONEYWELL-1825111-AQL

Sizes and colours

Offered as a single model

B2B Supply Info

CoverageAll regions
Project SupplyWe supply this breathing apparatus by the set for fire, rescue and marine teams.

Industrial Applications

B2B Sectors — Detailed Engineering Use Case

FirefightingA Type 2 set to EN 137:2006 with a 45-minute cylinder and an end-of-operation whistle.
Industrial emergency responseA full-face mask and demand valve for entry where breathing apparatus is required.
Ships and offshore unitsSOLAS, MED, IMO and MSC approvals for marine firefighting equipment.
Fire and rescue teamsFlame-retardant reflective shoulder pads and 3 carry handles.

Certificates & Standards

This set meets EN 137:2006 Type 2 and carries SOLAS, MED, IMO, MSC and ISO 23269-3 approvals, so you can specify it where Type 2 breathing apparatus or marine-approved equipment is required.

Approved standards

  • EN 137:2006 Type 2 — Self-contained open-circuit compressed air breathing apparatus with full face mask
  • MED — Marine Equipment Directive
  • SOLAS — International Convention for the Safety of Life at Sea
  • IMO / MSC — International Maritime Organization, Maritime Safety Committee
  • ISO 23269-3 — Ships and marine technology — Breathing apparatus for ships
  • EN 137:2006 Type 2 — Self-contained open-circuit compressed air breathing apparatus with full face mask
  • MED — Marine Equipment Directive
  • SOLAS — International Convention for the Safety of Life at Sea
  • IMO / MSC — International Maritime Organization, Maritime Safety Committee
  • ISO 23269-3 — Ships and marine technology — Breathing apparatus for ships

AQL_Datasheet_Armexia

Other files

Product documents

Download all documents2 files · 1,166 KB

FAQ

How long does the cylinder last?

The 7 L 300 bar carbon composite cylinder is rated for a 45-minute duration.

Is the cylinder supplied filled?

No. The cylinder is supplied empty and must be filled before use.

Which standards does it meet?

EN 137:2006 Type 2, with SOLAS, MED, IMO, MSC and ISO 23269-3 approvals.

Does it warn the user when air is running low?

Yes. It has an end-of-operation alarm whistle and a pressure gauge.

Which mask does it come with?

The Panoramasque full-face mask with a polycarbonate lens and a 5-point head strap.

Copyright © 2026 — Armexia — All Rights Reserved

We are committed to providing the highest quality standards for our customers.

Ratings and reviews