عربي

CO2 Suppression Systems

Total-Flooding CO2 Suppression Systems use carbon dioxide at high concentration (34-62% depending on fuel) to extinguish fires by oxygen displacement. They differ fundamentally from clean-agent systems by being hazardous to people and requiring mandatory evacuation before discharge. Designed for unoccupied areas and specific high-risk equipment.

(0 products)

About this category

CO2 suppression systems are among the oldest automatic gas systems and are still used in specific applications where alternatives are not viable. The design: high-pressure CO2 cylinders (50-70 bar) or low-pressure refrigerated storage (20 bar at -18°C), tight steel piping, distributed discharge nozzles, an independent fire-detection system, pre-discharge evacuation alarms, and a pneumatic safety lockout. Design concentration varies: around 34% for ordinary liquids, 50-62% for special fuels. Operating sequence: detection → audible/visual alarm → 30-60 s evacuation delay → CO2 discharge within one minute → holding concentration for 10-20 minutes. Applications: unoccupied generator rooms, transformer vaults, industrial battery rooms, printing and paint facilities, flammable-liquid storage, and manufacturing cells. A key advantage: high effectiveness on liquids and electrical, lower cost than clean agents, no residue. A substantive difference from FM-200 and Novec 1230: CO2 works by oxygen displacement (asphyxiation risk); clean agents work by heat absorption and chemical inhibition (used in occupied spaces only within design concentration and approved exposure limits). A critical technical note: total-flooding CO2 is prohibited in occupied areas due to the risk of death by asphyxiation; clear warning signage, personnel-entry lockout, and a documented evacuation plan are mandatory. Design, installation, and maintenance reference frameworks vary by model, application, and local requirements, so product and project documentation should be reviewed before procurement.

Read more

CO2 suppression systems are among the oldest automatic gas systems and are still used in specific applications where alternatives are not viable. The design: high-pressure CO2 cylinders (50-70 bar) or low-pressure refrigerated storage (20 bar at -18°C), tight steel piping, distributed discharge nozzles, an independent fire-detection system, pre-discharge evacuation alarms, and a pneumatic safety lockout. Design concentration varies: around 34% for ordinary liquids, 50-62% for special fuels. Operating sequence: detection → audible/visual alarm → 30-60 s evacuation delay → CO2 discharge within one minute → holding concentration for 10-20 minutes. Applications: unoccupied generator rooms, transformer vaults, industrial battery rooms, printing and paint facilities, flammable-liquid storage, and manufacturing cells. A key advantage: high effectiveness on liquids and electrical, lower cost than clean agents, no residue. A substantive difference from FM-200 and Novec 1230: CO2 works by oxygen displacement (asphyxiation risk); clean agents work by heat absorption and chemical inhibition (used in occupied spaces only within design concentration and approved exposure limits). A critical technical note: total-flooding CO2 is prohibited in occupied areas due to the risk of death by asphyxiation; clear warning signage, personnel-entry lockout, and a documented evacuation plan are mandatory. Design, installation, and maintenance reference frameworks vary by model, application, and local requirements, so product and project documentation should be reviewed before procurement.

No products in this category yet

Browse the similar categories, or request a quote for what you need and we will source it.