Emergency Lighting

Emergency Lighting keeps escape routes and exit signs lit when main power fails during a fire or other emergency. The category includes illuminated emergency exit signs, self-contained emergency luminaires with internal batteries, central battery systems, and pathway and corridor lighting. Backup duration after mains failure follows the adopted code (e.g. 90 minutes under NFPA 101, or 1-3 hours under EN 1838/EN 50172).

(0 products)

About this category

Emergency lighting types differ in backup power source and operating mode. Emergency exit signs carry the ISO 7010 running-figure pictogram and are lit continuously (maintained) or only on mains failure (non-maintained); photoluminescent variants require no power. Self-contained emergency luminaires carry an internal battery (NiCd or NiMH) charged from the mains and activate the moment power is lost — suited to small and medium facilities. Central battery systems serve larger buildings from a single battery bank or a few banks in a dedicated room, reducing maintenance cost by consolidating test points. Pathway and corridor luminaires provide a baseline level of light (typically 1 lux) along escape routes to allow safe movement. Luminaires differ in illuminance (1-50 lux), backup duration, and the option of periodic automatic self-testing through a smart system. Monthly short-duration testing (30 seconds) and annual full testing for the system's rated duration (e.g. 90 minutes under NFPA 101 or 1-3 hours under EN 50172) are mandatory. Specifications follow NFPA 101, EN 1838, and EN 50172.

Read more

Emergency lighting types differ in backup power source and operating mode. Emergency exit signs carry the ISO 7010 running-figure pictogram and are lit continuously (maintained) or only on mains failure (non-maintained); photoluminescent variants require no power. Self-contained emergency luminaires carry an internal battery (NiCd or NiMH) charged from the mains and activate the moment power is lost — suited to small and medium facilities. Central battery systems serve larger buildings from a single battery bank or a few banks in a dedicated room, reducing maintenance cost by consolidating test points. Pathway and corridor luminaires provide a baseline level of light (typically 1 lux) along escape routes to allow safe movement. Luminaires differ in illuminance (1-50 lux), backup duration, and the option of periodic automatic self-testing through a smart system. Monthly short-duration testing (30 seconds) and annual full testing for the system's rated duration (e.g. 90 minutes under NFPA 101 or 1-3 hours under EN 50172) are mandatory. Specifications follow NFPA 101, EN 1838, and EN 50172.

All products in Emergency Lighting

No products in this category yet

Browse the similar categories, or request a quote for what you need and we will source it.