Sprinkler Systems

Sprinkler Systems are fixed suppression systems that activate automatically when zone temperature rises to a defined point (typically 68°C). The category includes wet-pipe systems, dry-pipe systems, pre-action systems, deluge systems, sprinkler heads in all types, and fire pumps. System type is selected against contents and ambient temperature.

(0 products)

About this category

Sprinklers do not fire all at once like in the movies; each head activates independently when its glass bulb bursts or its fusible link releases. Wet-pipe systems hold pressurized water in the piping and serve buildings above freezing — the most common type. Dry-pipe systems hold compressed air; water enters only when a head opens, serving cold areas such as unheated warehouses and parking garages. Pre-action systems admit water according to their interlock type; double-interlock systems require two events before water enters (fire detection and a sprinkler opening), serving water-sensitive environments such as server rooms and libraries. Deluge systems use open heads and release water from every head simultaneously for high-hazard sites such as fuel-storage tanks. Sprinkler heads come in pendent, upright, and sidewall patterns and several activation temperatures. Fire pumps supply the pressure the system requires. Specifications follow NFPA 13 and EN 12845; designs are reviewed by a licensed fire engineer.

Read more

Sprinklers do not fire all at once like in the movies; each head activates independently when its glass bulb bursts or its fusible link releases. Wet-pipe systems hold pressurized water in the piping and serve buildings above freezing — the most common type. Dry-pipe systems hold compressed air; water enters only when a head opens, serving cold areas such as unheated warehouses and parking garages. Pre-action systems admit water according to their interlock type; double-interlock systems require two events before water enters (fire detection and a sprinkler opening), serving water-sensitive environments such as server rooms and libraries. Deluge systems use open heads and release water from every head simultaneously for high-hazard sites such as fuel-storage tanks. Sprinkler heads come in pendent, upright, and sidewall patterns and several activation temperatures. Fire pumps supply the pressure the system requires. Specifications follow NFPA 13 and EN 12845; designs are reviewed by a licensed fire engineer.

All products in Sprinkler Systems

No products in this category yet

Browse the similar categories, or request a quote for what you need and we will source it.